About this documentation

VERWEISZIELPUNKT

This documentation describes the set-up and operation of the Remote HMI Device Manager, henceforth referred to as "software" for short.

The purpose of the software is to parameterise the Remote HMI firmware and manage the firmware licences. The Remote HMI firmware is henceforth referred to as "firmware" for short.

 

VERWEISZIELPUNKT
The firmware with its functions is described in a separate manual, and for remote access to the firmware please also refer to the notes and instructions of the firmware manual.

 

VERWEISZIELPUNKT

Registered trademarks

VERWEISZIELPUNKT

The products and services referred to in this documentation are registered trademarks and as such the property of their manufacturers.

 

VERWEISZIELPUNKT

Target group

VERWEISZIELPUNKT

This documentation is intended for administrators and production engineers who are authorised to parametrise HMI systems and set up remote connections.

 

VERWEISZIELPUNKT

Layout features

VERWEISZIELPUNKT

This documentation uses the following symbols, highlights and notes:

 

Notes on system security and how to avoid data loss

 

Important information on workflow and its optimisation

 

Notes on Pro licence functions

 

List

 

 
Heading of an instruction
First step
Interim result
Second step
Result of action

 

 Apply 

indicates a button on the user interface

Dashboard

indicates a register, menu or a function of the user interface

[F8]

indicates a key of the keyboard

 

 

 

VERWEISZIELPUNKT

Contact details

VERWEISZIELPUNKT

R. STAHL HMI Systems GmbH

Adolf-Grimme-Allee 8

50829 Köln

Germany

 

Telephone:

+49 221 76806-1200

Facsimile:

+49 221 76806-4200

Homepage:

r-stahl.com/de

 

VERWEISZIELPUNKT
Contact data Support

Telephone:

+49 221 76806-5000

E-mail

[email protected]

 

VERWEISZIELPUNKT

Description

VERWEISZIELPUNKT

The software complements the firmware and is used for central parameterisation and licence management. The software access to the firmware must be granted in the Thin Client firmware under the System & Proxy menu item. Once access has been granted, several Thin Clients can be configured and parameterised via templates with the same settings.

Access to the Thin Client is also possible via the Remote Access function. This remote access via VNC must be permitted under the System & Proxy menu item in the firmware.

 

VERWEISZIELPUNKT

The software can be installed on a workstation or on a server. It can be used by multiple users.

 

VERWEISZIELPUNKT

The software supports the management of templates and device settings in databases. Each database can be password-protected against unauthorised access.

 

VERWEISZIELPUNKT

Licencing models

VERWEISZIELPUNKT

A licence key must be activated in order to use the software.

Without a licence key the software works as a demo version limited to one Thin Client with Remote HMI Firmware version 6 or above.

 

The following licence models are available for the management of multiple Thin Clients:
Single licence to manage one additional Thin Client
Package licence to manage 5 Thin Clients
Package licence to manage 10 Thin Clients
Package licence to manage 25 Thin Clients

 

The user activates the licence key in the software and connects it with the PC or server on which the software is installed.

 

VERWEISZIELPUNKT
The following firmware licences are available:
Basic
Basic licence for establishing remote connections, configuring the firmware and for importing and exporting settings.
The use of the Device Manager is activated via the device hardware, which also ensures the activation of a Pro package licence.
Pro
Licence extension for using and managing applications, using multiple parallel remote connections, importing and exporting settings.
The additional functions are unblocked by activating the Pro licence.

 

The Pro package licences of the firmware can only be used together with the Device Manager. It is not possible to activate the package licences in the Thin Client's firmware.

 

The following Pro licence models of the firmware are available for the Thin Clients:
Pro single licence
Pro package licence for 5 Thin Clients
Pro package licence for 10 Thin Clients
Pro package licence for 25 Thin Clients

 

The size of the management licence for the Device Manager must be the same as that of the Pro package licence. This means that in order to use a Pro package licence for 10 Thin Clients, a management licence for 10 Thin Clients must be available in the Device Manager.

 

VERWEISZIELPUNKT

Notes on the firmware

VERWEISZIELPUNKT

Function

VERWEISZIELPUNKT

The Remote HMI V6 firmware is a Thin Client software developed for the process industry which is supplied together with R. STAHL SERIES 500 operating devices. It is used to establish and secure remote connections to one or more workstations or application servers. This makes remote access from one operating station to one or more workstations or servers possible.

 

VERWEISZIELPUNKT
Suitable for device platforms:
EAGLE series 5X6
MANTA series 5X7
MANTA GMP series 5x9
SHARK series 5X8
Industrial Box PC
Tablet series EX80
Tablet series FT110

 

VERWEISZIELPUNKT

The devices are connected to the Ethernet via the Ethernet interface (copper or fibre optic). The number of available Ethernet adapters varies depending on the device platform.

 

VERWEISZIELPUNKT

Supported remote protocols

VERWEISZIELPUNKT

The HMI operating stations and the Industrial Box PCs are integrated as Thin Clients and use the available network resources. Depending on the network architecture and access authority level, a remote connection can be established via the IP address to any Ethernet station. The firmware supports the Remote Desktop Protocol (RDP), Virtual Network Computing (VNC) and Keyboard Video Mouse over Internet Protocol (KVM over IP). The Thin Client can use the firmware to call up applications installed on the connected workstations or installed on virtual servers.

 

 

The illustration shows a redundant virtual network. It connects Thin Clients via an RDP, VNC or KVM-over-IP connection with workstations and servers. In such a network, every Thin Client can access connected systems and call up applications from there.

 

VERWEISZIELPUNKT

RDP

VERWEISZIELPUNKT

RDP connection About RDPThe Remote Desktop Protocol (RDP) is a protocol for remote access. It can be used to display and control screen content of a remote workstation. RDP is an integral part of all Windows operating systems.

A special session is started on the server for the RDP access, and only the connected client can access this session.

The size of the displayed screen content is determined on the Thin Client's display size. If the screen content is only displayed on one half of the Thin Client it will be scaled accordingly.

A Windows server is required for several RDP connections to access one server. A client access licence is required for each client to access and connect to the Windows server. Licencing depends on the operating system of the server.

Either the computer name or the server IP address can be used for addressing.

If you want the option of redundant connections we recommend you use the DNS naming system.

 

VERWEISZIELPUNKT

VNC

VERWEISZIELPUNKT

VNC connection About VNCVirtual Network Computing (VNC) is a platform-independent server system. VNC operates according to the Client-Server model.

The VNC service displays the screen content of a remote PC (server) on a local computer (client) The client sends the keyboard and mouse actions to the remote server. This way, the client can use the resources, applications and programs of the server.

The server's display size determines the size of the displayed screen content. If the server display screen ratio is different to that of the Thin Client, the screen content will be compressed or displayed with black edges.

VNC allows multiple access to the server. The display of the clients is then synchronised.

The VNC service must be installed on the remotely controlled PC (host). The Thin Client accesses the VNC server via a VNC viewer application. The installation and configuration of the VNC system on the server and the client requires administrator access authority. The VNC communication between server and client does not require this level of access authority.

VNC services are available from various providers. Depending on the VNC server, these systems have different functionalities.

 

For detailed information and a description of the VNC service, please refer to the documentation of the provider.

 

In order to be able to establish a VNC connection, the VNC server system must be activated on the host. The VNC service acquires the IP address needed for this connection from the settings of the PC's network connection. Depending on the configuration, the IP address is specified manually or allocated by a DHCP server. In the firmware's address book, this IP address is defined as the server IP of the VNC connection.

 

The way this connection is established depends on the settings of the VNC server and can either be
a direct connection that is not password-protected
a connection with VNC password
a connection with Windows password

 

VERWEISZIELPUNKT

KVM over IP

VERWEISZIELPUNKT

KVM-over-IP connection About KVM over IP

KVM over IP provides remote access to keyboard-video-mouse systems (KVM). With these systems, a workstation is connected with keyboard, mouse and screen via an external KVM-over-IP box. The KVM-over-IP box is integrated into the network via an Ethernet interface. Data transmission is via the VNC protocol. A VNC service has been installed to establish the connection. The workstation that is part of the KVM system does not require a network connection or a software installation.

 

VERWEISZIELPUNKT

User roles

VERWEISZIELPUNKT

The access control system of the Remote firmware is based on three user roles. These are tiered in a hierarchy.

 

User role

Description

Operator
(standard user)

The operator can switch between the displays of the connected systems and operate these systems remotely. The operator has access to the basic settings. He or she cannot make any changes to the firmware.

Engineer

The production engineer can set up, parametrise and delete remote connections. With the Pro licence, the engineer can add existing applications in the firmware. He or she cannot access the Windows user interface of the Thin Client.

 

The engineer can adjust the following settings:
Displays
User Interface
Connections
Keyboard Wedge

Admin

The administrator has full access authority to the Windows user interface of the Thin Client. In addition to the options available to the production engineer, the administrator can install third-party applications and drivers on the Thin Client. He or she can configure the network, make system settings via the Remote HMI menu user interface and log into the regular Windows user interface as Admin.

 

The following adjustments in the Settings can only be made by the administrator:
Maintenance
System & Proxy
Protection
Access Control
Import & Export
Update

 

The Admin and Engineer user roles can be password-protected in the "Access Control" menu.

When the firmware is started up for the first time, the user roles are de-activated and the firmware starts with the Admin user role. Password protection is not active.

 

The Admin and Engineer user roles should only be given to staff familiar with Thin Client administration.

 

VERWEISZIELPUNKT

User interface

VERWEISZIELPUNKT

The software will start with the following screen.

 

1 Current database
2 Navigation element, change to main menu
3 Display Devices menu
4 Display Templates menu
5 Work area or preview
6 Call up event log
7 Button for adding devices

 

VERWEISZIELPUNKT
Navigation elements

opens menu

closes menu

 

VERWEISZIELPUNKT
Operating elements

Operating elements vary depending on the menu.

 

Element

Meaning

Switch activated

Switch deactivated

Button
A greyed-out button is unavailable

Input field

Scroll bar

Check box activated

Check box deactivated

 

VERWEISZIELPUNKT

Menus

VERWEISZIELPUNKT

Main menu

VERWEISZIELPUNKT

Use the main menu to set up the software.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT

The main menu contains the following functions:

 

Menu entry

Description

Open Database

open existing database

New Database

create new database

Set / Reset Database Password

Set or reset password for the database

Settings

Open settings menu

License Manager

Open licence manager

Firmware Update

Update firmware

About

Information on the Device Manager

Legal Notice

Information on the licence terms of the Device Manager

 

VERWEISZIELPUNKT

Databases

VERWEISZIELPUNKT

You can save the templates and the firmware configurations of the connected devices in databases. The software saves the data in RDM files (name.rdm). You can protect these files with a password.

 

VERWEISZIELPUNKT

Licence management

VERWEISZIELPUNKT

The License Manager menu contains two registers to manage the licences.

 

Remote HMI Device Manager contains the number of management licences
Remote HMI (Pro License) contains the number of Pro licences of the firmware

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT

The structure of the lists and the editing options depend on the register.

 

Remote HMI Device Manager register
The list of package licences is made up of the following columns:
Product key Package licence product key
Description Licence description
Package Number of licences
Company Licence holder
Database Database to which the licence has been allocated
Action Editing options

 

You can search for product keys in the Search Product Key field.

 

Editing options in the Remote HMI Device Manager register

 Assign 

assigns licence to the current database

 Release 

releases licences for the current database

 Add product key 

adds a product key

 

Register Remote HMI (Pro licence)
The list of devices consists of the following columns:
Name Device name in the firmware
Type Device type
Folder/Group Folder of the device menu to which the Thin Client was added
Installation ID
Pro License Status Licence status;
if an action is carried out, a progress bar will appear in this field
Action Editing option

 

You can search for device names in the Search to search for device names. You can narrow down the search by filtering with the Type or Folder/Group columns.

 

Editing in the Remote HMI (Pro Licence) register

 Get License Status 

calls up the firmware licence status of the device

 Add product key 

adds a product key

 

VERWEISZIELPUNKT

Software-Settings

VERWEISZIELPUNKT

Use the Settings menu to set up the software.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT
Functions in the Settings menu

Database

specifies how the database reacts during start-up

Size

specifies the text and element size of the user interface

Request Download Timeout

specifies the reaction time (timeout) for the user to confirm or reject the acceptance of the device data.

 

0 seconds; confirmation by user not possible (force download)
1 to 120 seconds

Logfile

activates the debugging log function (logfile)

 

VERWEISZIELPUNKT

Firmware Updates

VERWEISZIELPUNKT

Go to the Firmware Updates menu for a list of available devices and to initiate a firmware update.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT
The list consists of the following columns:
Name Thin Client name in the firmware
Type Thin Client type
Folder/Group Folder of the device menu to which the Thin Client was added
Current version Firmware release information
Progress / Status Licence status (none, Pro); if an action has been activated, a progress bar will be shown
Action Editing options

 

Use the Search to search for device names. You can narrow down the search by filtering with the Type or Folder/Group columns.

 

Options in the Firmware Updates menu

 Select Firmware File 

opens the search window

 Start Download 

downloads the firmware update to the Thin Client

 Show changelog 

shows the change log

 

For an update to be carried out successfully, the UWF filter must be deactivated in the firmware.

 

VERWEISZIELPUNKT

Devices menu

VERWEISZIELPUNKT

Go to the Devices menu to add devices to a database and edit them. You can manage address book and applications for each device.

 

VERWEISZIELPUNKT
1 Menu functions
2 Device information
3 Register bar
4 Register functions
5 Button for adding a licence
6 Device data, imported from device

 

VERWEISZIELPUNKT
Functions in the Devices menu

The devices are listed and managed in folders. The menu contains the following elements:

 

1 Edit mode Open edit mode
2 Number of devices in folder
3 Status of connection to device
4 Add Device Adding a device
5 Expand or collapse folder

 

VERWEISZIELPUNKT
Edit mode

You have the following options in the edit mode:

 

1 Edit mode Open edit mode
2 Rename selected item
3 Add folder Adding a folder
4 Revert all revert all entries
5 Delete selected item

 

VERWEISZIELPUNKT
Status of connection to device

Symbol

Meaning

connected

unavailable, no response to ping request

available, not connected

 

VERWEISZIELPUNKT
Register functions

The software supports the import and transmission of the firmware configuration and the storage of entries in the Address Book and Applications registers as templates.

You have the following options:

 

Update from device

Import the settings of the selected Thin Client

Save as Template

Save settings as template

Send configuration

Transmit configuration to Thin Client

 

VERWEISZIELPUNKT
Register

The register bar contains the following functions:

 

Register

Description

Overview

Overview of system and connection information, display of event log for device

Address Book

Diagnosis and management of remote connections

Applications

Display and management of applications

Networks

Display and set-up of the network adapters

only available with remote access

Settings

Menus for display and set-up of system, security and network parameters

only available with remote access

 

VERWEISZIELPUNKT

Templates menu

VERWEISZIELPUNKT

Use the Templates menu to save address book entries and applications as templates, edit and send them to a device.

 

VERWEISZIELPUNKT
1 Menu functions
2 Template information
3 Register bar
4 Register functions
5 Functions for editing the entries
6 Register entries (here: address book entries, i.e. remote connections)

 

VERWEISZIELPUNKT

The Templates menu consists of two registers.

 

Address book (see Address book)

 

VERWEISZIELPUNKT
Functions in the Templates menu

+ Add New Template

 

 

When a template has been opened, you have the following options:

 

VERWEISZIELPUNKT

Delete

 

Rename

 

Send configuration

to Thin Client

 

VERWEISZIELPUNKT

Register

VERWEISZIELPUNKT

Overview

VERWEISZIELPUNKT

The Overview register shows the current device data and the last actions in the event log.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT

Address book

VERWEISZIELPUNKT

Use the Address Book register to call up or manage configured remote connections or create new remote connections.

 

VERWEISZIELPUNKT

Address book options

VERWEISZIELPUNKT

The Address Book register lists all configured remote connections.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT
Register functions

The software supports the import and transmission of the firmware configuration and the storage of entries in the Address Book and Applications registers as templates.

You have the following options:

 

Update from device

Import the settings of the selected Thin Client

Save as Template

Save settings as template

Send configuration

Transmit configuration to Thin Client

 

VERWEISZIELPUNKT
Navigation elements

opens an item in the list

closes an item in the list

 

VERWEISZIELPUNKT
Address book functions

The available edit functions or buttons depend on the sub-menu.

 

Add

Adds a new entry.

Clear all

Deletes all entries in the list

Edit

Opens the highlighted entry for editing

Copy

Copies the highlighted entry and opens the copy for editing

Delete

Deletes the highlighted entry

Manage

Navigates back to the list level

Apply

Applies input

Revert

Rejects input

Up

Moves the highlighted entry one place up in the list

Down

Moves the highlighted entry one place down in the list

Edit profile

Opens the dialogue for editing the remote profile

 

VERWEISZIELPUNKT
Hotkey for calling up remote connections

You can call up the remote connection via the keyboard if you have specified a hotkey under the Hotkey function. Three keys can be specified.

 

First key

Second key

Third key

[Shift]

[Ctrl]

none

[Ctrl]

[Alt]

[F1] ... [F12]

 

The Ctrl key must not be selected twice.

 

VERWEISZIELPUNKT

Notes on the firmware

VERWEISZIELPUNKT

The menus and operating elements look different in the firmware and in the software. Menu items with identical names have identical functionality.

 

VERWEISZIELPUNKT
If a connection in the address book is greyed out, the user's authority level is too low to access it.

 

VERWEISZIELPUNKT
Status of the remote connection

Symbol

Meaning

connected

not connected

connection not possible

 

default, will be connected automatically during start-up

 

connected, parallel remote connection, active in the background (multi-session connections require a Pro licence)

 

VERWEISZIELPUNKT
The simultaneous use of multiple remote connections (multi-session connection) requires the Pro licence and must be activated in the Connections menu.

 

If the parallel use of several remote connections has been activated, the connections will be displayed as follows:

 

 

VERWEISZIELPUNKT

App management

VERWEISZIELPUNKT
Requires a Pro licence.

 

VERWEISZIELPUNKT

Use the Applications register to add and manage links to Windows tools and applications, virus protection software or EXE applications such as the Citrix Receiver. You can configure the display and behaviour of an app with various settings, and manage access via the user roles.

Before you can add an app you need to install it on the Thin Client. The Thin Client has to meet the system requirements of the app.

 

VERWEISZIELPUNKT

Options in the Applications register

VERWEISZIELPUNKT

The Applications register shows the connected Apps.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT
Register functions

The software supports the import and transmission of the firmware configuration and the storage of entries in the Address Book and Applications registers as templates.

You have the following options:

 

Update from device

Import the settings of the selected Thin Client

Save as Template

Save settings as template

Send configuration

Transmit configuration to Thin Client

 

VERWEISZIELPUNKT
Navigation elements

opens an item in the list

closes an item in the list

 

VERWEISZIELPUNKT
Functions in the Applications register

The available edit functions or buttons depend on the sub-menu.

 

Add

Adds a new entry.

Clear all

Deletes all entries in the list

Edit

Opens the highlighted entry for editing

Copy

Copies the highlighted entry and opens the copy for editing

Delete

Deletes the highlighted entry

Manage

Navigates back to the list level

Apply

Applies input

Revert

Rejects input

Up

Moves the highlighted entry one place up in the list

Down

Moves the highlighted entry one place down in the list

Terminate

only available with remote access

Forces the shut-down of an open application with possible loss of data

Select file

only available with remote access

Opens the selection window for executable files

 

VERWEISZIELPUNKT
Hotkey for starting applications

An application can be selected via the keyboard if a hotkey has been created under the Hotkey menu item. Three keys can be specified.

 

First key

Second key

Third key

[Shift]

[Ctrl]

none

[Ctrl]

[Alt]

[F1] ... [F12]

 

The Ctrl key must not be selected twice.

 

VERWEISZIELPUNKT
Each hotkey can only be allocated once.

 

VERWEISZIELPUNKT
Command line parameters

You can define a command line parameter for each app that allocate application-specific parameters.

Example:
In the browser, the -k www.stahl.de parameter entry calls up the website www.stahl.de in the kiosk mode.

 

Please refer to the description of each application for information on permitted command line parameters.

 

VERWEISZIELPUNKT
Application privilege level

Level

Meaning

Run as standard user

Starts the application with standard user authority

Run as administrator user

Starts the application with Administrator authority

You can define name and password for the Admin account in the System & Proxy menu.

Run elevated

Starts the application with extended Administrator authority

You can define name and password for the Admin account in the System & Proxy menu.

 

VERWEISZIELPUNKT

Notes on the firmware

VERWEISZIELPUNKT

The menus and operating elements look different in the firmware and in the software. Menu items with identical names have identical functionality.

 

VERWEISZIELPUNKT
Symbols in the list of apps

You can freely chose the icons representing the apps in the list. In the interest of user-friendliness we recommend you use commonly used symbols.

 

Symbols

A selection of icons standing for different types of app.

Engineer, Admin: Defines who is authorised to start the app.

If no symbol is shown all user roles are authorised to start the app.

default, will be connected automatically during start-up

 

VERWEISZIELPUNKT

Network

VERWEISZIELPUNKT
Read only
The settings can only be changed remotely (see Remote access to a device).

 

VERWEISZIELPUNKT

Use the Networks register to configure the Thin Client for incorporation in the network.

The number and designation of available Ethernet adapters depend on the Thin Client's hardware.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT

Options in the Networks register

VERWEISZIELPUNKT
Settings on the Windows network level can have an impact on the entire network. Only click on the Advanced if you know your way around Windows network settings. If not, ask your network administrator for help.

 

VERWEISZIELPUNKT
Buttons in the Networks register

Advanced functions

Opens the Windows network settings

Apply

Applies input

Revert

Rejects input

Create/remove team

Opens the teaming function dialogue

Renew IP settings

Requests renewed IP configuration from the DHCP server

 

VERWEISZIELPUNKT

Adapter information

VERWEISZIELPUNKT

The Adapter section lists information on the chosen Ethernet adapter.

 

Name

Name of the Ethernet adapter

MAC

MAC address of the Ethernet adapter

Driver

Version of the adapter driver

Speed

Speed of the Ethernet connection

Status

Status of Ethernet connection

 

VERWEISZIELPUNKT

Settings

VERWEISZIELPUNKT
Read only
The settings can only be changed remotely (see Remote access to a device).

 

VERWEISZIELPUNKT

The Settings register contains many functions with which the Engineer or Admin can configure the firmware.

 

VERWEISZIELPUNKT

Options in the Settings register

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT

The Settings register contains the following menus:

 

Menu

Contents

Authorised user

Information

Current system data, settings and configurations

The menu contents vary depending on the device platform.

 

Maintenance

Functions required for the maintenance of the Thin Client. Allows addition of third-party software and drivers.

Activation of Pro licence and Windows LTSB

Admin

System & Proxy

Settings concerning device name (in the network) and proxy server

Engineer / Admin

Protection

Settings concerning system security

Engineer / Admin

Displays

Settings for up to 6 displays

Engineer / Admin

User Interface

Behaviour of RemoteHMI menu

Admin

Access Control

Setting up of protected user roles

Admin

Connections

Settings of connection options

Engineer / Admin

Keyboard Wedge

Setting up the COM interfaces for external scanners or readers

Engineer / Admin

Import & Export

Functions for the export and import of the device configuration

Engineer / Admin

Updates

Firmware updates

Admin

Legal Notice

Information on licence terms and conditions for the software used on the Thin Client

 

 

VERWEISZIELPUNKT

Display of system information

VERWEISZIELPUNKT

The Information menu lists the current system data, settings and configurations. The menu contents vary depending on the device platform.

 

Menu

Contents

Main

Essential system information, OS image and firmware version

System

Information on hardware and operating system

This varies depending on the device type.

Network

Information on computer name and addresses of the proxy server, the device and the gateway

Remote Access

Information on the status of the remote connections

Protection

Up-to-date information on system security

Submodules

List of sub-module versions

 

VERWEISZIELPUNKT

Remote Access

VERWEISZIELPUNKT

The settings in the Settings and Networks firmware registers can only be changed via remote access.

 

The remote access must be permitted in the firmware under System & Proxy . Depending on the settings a password might be required.

 

VERWEISZIELPUNKT

 

VERWEISZIELPUNKT

Licence management

VERWEISZIELPUNKT
 
Opening the main menu
Click on to open the main menu.

 

VERWEISZIELPUNKT
 
Adding a software licence
Open the License Manager menu.
In the Remote HMI Device Manager menu, click on  Add new product key .
The system will open the activation dialogue.

 

 
Adding a firmware licence
Open the License Manager menu.
In the Remote HMIs (Pro License) register, click on  Get License Status .
The list shows the installation ID and the licence status.
In the Remote HMI Device Manager register, click on  Add product key , if you want to activate a Pro licence.
The system will open the activation dialogue.

 

 
Adding a firmware licence in the Devices menu
Mark the device in the Devices menu.
Click on  Add Pro License , if you want to activate a Pro licence.
The system will open the activation dialogue.

 

VERWEISZIELPUNKT
Carrying out the activation dialogue
If the PC has internet access, you can activate the Pro Licence online via the software.
If not, you need to request the activation code from remotehmi-licensing.stahl.de .

 

 

Under Product key , enter the licence key you received.
Under Company Name , enter your company name.
Under Name , enter the name of the licence holder.
Under Email Address , enter the e-mail address of the licence holder.
Click on  Activate Online  to activate the licence online.
Click on  Activate Offline  to activate the licence offline.

 

 
Activating the licence online via internet access
Make sure the PC has internet access.
Click on  Activate Online .
The system will start the activation process.
If the activation has been successful, the system will issue a corresponding message, and the licence key will be shown in the list.

 

 
Activating the licence offline
In order to activate the licence you will need the installation ID and the product key (licence key). You will also need a device with internet access.

 

In the browser, go to the following website: remotehmi-licensing.stahl.de.
Select "License Activation".
Fill in the form and request the activation code.

 

 

You will receive an e-mail with the activation code to the e-mail address specified in the form. This may take up to five minutes. If you receive no such e-mail, please check your spam folder.

 

In the Activate License window, click on  Activate Offline .

 

 

Under Product key, enter the product key.
Under Activation Code, enter the activation code you were given.
Under Company Name, enter your company name.
Under Name , enter the name of the licence holder.
Under Email Address , enter the e-mail address of the licence holder.
Click on  Activate Offline .
The system will start the activation process.
If the activation has been successful, the system will issue a corresponding message, and the licence key will be shown in the list.

 

VERWEISZIELPUNKT

Adding and managing devices

VERWEISZIELPUNKT
 
Adding a device
Open Devices.
Click on  Add Device to open the search window.
Click on  Start Scan.
The network will be searched for available devices. The title bar will show the number of available and new devices.
If all devices have already been added, the list of search results will be empty.
Select the device you want from the search results.
Confirm your selection.
The device will be added to the list.

 

VERWEISZIELPUNKT
 
Open edit mode
Open Devices.
Click on Edit mode to open the edit mode.
Highlight the entry and click on Rename selected item to rename the device or the folder.
Highlight the entry and click on Delete selected item to delete the device or the folder.
Click on Add folder to add a folder.
Click on Revert all to revert all entries.

 

VERWEISZIELPUNKT
 
Adding a folder
Open Devices.
Activate the edit mode.
Click on  Add Folder .
Enter a name and confirm the entry.
The folder will be added.

 

VERWEISZIELPUNKT
 
Reading device data (Update from Device)
Reading the device data will overwrite the current software settings.

 

Open Devices.
Highlight a device.
Click on  Device section .
Confirm with  Yes .
The system will adopt the configuration and issue a message.

 

VERWEISZIELPUNKT
 
Creating a template of a device
Open Devices.
Highlight a device.
Click on  Save as Template .
The Save as Template window will pop up.
Enter a name and confirm the entry.
The template will be saved.

 

VERWEISZIELPUNKT
 
Sending a configuration to the device
Open Devices.
Highlight a device.
Click on  Send configuration .
The Download to device window will pop up.
Use the Force Download function to force the download of all changes. It is not possible for the Thin Client user to abort the download.

 

Activate Force Download if you want to force the download.
Click on  Start download .
A progress bar shows how the data transfer is progressing.
If you want to abort the transfer, click on  Cancel .
The system will issue a message.

 

VERWEISZIELPUNKT

Notes on settings options

VERWEISZIELPUNKT
Automatic logon at the server

The automatic logon at the server can be configured in the settings of the remote connection. For this you need the user ID and the password for the server.

 

Only users with authority for remote access to the server can log on to the server. Check the user authority at the server or the KVM box.

 

VERWEISZIELPUNKT
Display position of the server screen

Different parts of the server screen can be displayed. You can configure the display via Show on when creating the remote connection.

 

VERWEISZIELPUNKT

The following display options are available:

 

Symbol

Name

Meaning

Full display

shows the full screen

Left display half

Scales the remote screen content and displays it on the left hand side

Right display half

Scales the remote screen content and displays it on the right hand side

Upper display half

Scales the remote screen content and displays it at the top half

Lower display half

Scales the remote screen content and displays it at the bottom half.

 

VERWEISZIELPUNKT
Behaviour of firmware when connection is lost

You can configure how the remote connection behaves during a system startup or when it is lost, as follows:

 

Auto connect on system startup

On

Automatically establishes a connection during system startup, is represented by the symbol in the address book entry

Off

During a system startup the dial-up must be started manually

Auto reconnect on connection loss

On

Automatically reconnects after the connection has been lost

Off

After the connection has been lost, the dial-up must be started automatically

 

VERWEISZIELPUNKT

Set-up of RDP connections

VERWEISZIELPUNKT

You will need the IP address or the name of the server for the configuration. These are stored in the system properties of the server.

 

For RDP connections, remote access must be explicitly permitted in the server's system properties. The remote access must be configured for the user.

 

Open the Address Book register.
Click on  + Add .
A new address book entry is created.
Click on  Edit .
In Connection Settings, via the drop-down field Type, select "RDP".
Under Name, enter the name of the connection.
Under Server Address, enter the IP address or the name of the server.
To ensure automatic access to the connected server you have to enter the correct logon data. Please note that a domain name may have to be used together with the user name.

 

Under User Name and Password, enter the logon data of the server.
If you want to be able to call up the remote connection via the keyboard, use Hotkey to specify a hotkey.
Click on Show on to select the display option.
Specify the minimum user role required for the manual set-up of the connection.
If a user does not have the required authority to set up the connection, this connection is greyed out in the address book.

 

Click on  Apply  to set up the connection.
The connection is shown in the address book.

 

VERWEISZIELPUNKT

Set-up of the VNC connection.

VERWEISZIELPUNKT

The VNC software must be installed on the Thin Client and the server, requiring Administrator authority on both.

To set up the connection you require the IP address of the VNC server and, depending on the configuration, the VNC password.

 

VERWEISZIELPUNKT
If the port number of the VNC server is different from the standard port, the IP address needs to be extended to include the port number, for example: 192.168.1.23:5901

 

Open the Address Book register.
Click on  +Add .
A new address book entry is created.
Click on  Edit .
In the Connection Settings, select "VNC" from the Type drop-down field.
Under Name, enter the name of the connection.
Under Server Address, enter the IP address of the server.
To ensure automatic access to the connected server you have to enter the correct logon data.

 

Enter the logon data of the server.
If you want to be able to call up the remote connection via the keyboard, use Hotkey to specify a hotkey.
Under Show on, select the display option.
Specify the minimum user role required for the manual set-up of the connection.
If a user does not have the required authority to set up the connection, this connection is greyed out in the address book.

 

Click on  Apply  to set up the connection.
The connection is shown in the address book.

 

VERWEISZIELPUNKT

Preparation of host for VNC connection

VERWEISZIELPUNKT

The process varies according to which VNC service is used. For more information, please refer to the documentation provided by the VNC service manufacturer.

 

This process requires Administrator authority.

 

Make sure that the Thin Client can contact the host. If both are part of the same network, this will be the case.
Make sure the VNC service is installed and activated on the host (see Activating VNC server system on the host).
If the network connection is protected via a firewall you need to configure this firewall. Permit network communication via the port where the VNC service is ready to receive (5900 as a standard).
If the network connection is protected via a router, you need to configure this router. For the transfer of network communication, specify every configured port where the VNC service is ready to receive (5900 as a standard).
Check whether the VNC service is working properly and whether it accepts incoming connections.
The host is ready.

 

VERWEISZIELPUNKT

Preparation of Thin Client for the VNC connection

VERWEISZIELPUNKT

The process varies according to which VNC service is used. For more information, please refer to the documentation provided by the VNC service manufacturer.

 

This process requires Administrator authority.

 

Make sure that the Thin Client can contact the host. If both are part of the same network, this will be the case.
If the VNC connection of the Thin Client is protected via a proxy server you have to specify the proxy server in the VNC viewer.
The Thin Client is ready

 

VERWEISZIELPUNKT

Test of remote connection

VERWEISZIELPUNKT
This test can only be conducted via remote access to the Thin Client.

 

VERWEISZIELPUNKT
VERWEISZIELPUNKT

Managing remote connections

VERWEISZIELPUNKT
In order to be able to edit the settings, the connection must be inactive.

 

 
Moving connections in the list
Open the entry in the Address Book register with .
Click on to move the entry up one place in the list.
Click on to move the entry down one place in the list.
The connection is moved in the list.

 

 
Editing connection settings
Deactivate the connection in the Address Book register.
Open the entry.
Click on  Edit  to edit the settings.
Change the settings as required.
Click on  Apply  to accept the changes.
Click on  Revert  to reject the changes.
Click on  Manage  to edit the list.
Click on [] to close the entry and return to the list.

 

 
Deleting a connection
Deactivate the connection in the Address Book register.
Open the connection.
Click on  Delete  to delete the connection.
Confirm the security message.
The connection is deleted.

 

 
Copying a connection
Deactivate the connection in the Address Book.
Open the entry.
Click on  Copy  to copy the settings.
A new entry is created.
Open the entry and edit the settings as required.
Click on  Apply  to accept the changes.
Click on  Revert  to reject the changes.
Click on  Manage  to edit the list.
Click on [] to close the entry and return to the list.

 

VERWEISZIELPUNKT

Remote access to a device

VERWEISZIELPUNKT
The remote access must be permitted in the firmware under System & Proxy . Depending on the settings a password might be required.

 

 
Connecting to the device
Under Devices, select the device you want to access remotely.
The device configuration will pop up.
Select the Remote Access register.
Click on Connect to connect to the Thin Client.
Once the connection has been established, a preview of the screen content of the Thin Client will pop up.

 

 

Click on Fullscreen to switch to full screen mode.

 

VERWEISZIELPUNKT
Please also refer to the notes and instructions of the firmware manual.

 

VERWEISZIELPUNKT
 
Disconnecting the remote connection
Click on Disconnect to actively disconnect the connection.
On exiting the Remote Access register, the connection will be disconnected.

 

VERWEISZIELPUNKT

Adding apps

VERWEISZIELPUNKT
Requires a Pro licence.

 

VERWEISZIELPUNKT

Compatibility with third-party software

The firmware is qualified for software that is included in the delivery of the supported HMI devices. R. STAHL HMI Systems GmbH does not accept any liability for the functionality of the software of any other providers. Before installing software of other providers make sure it is compatible.

 

 
Checking system requirements and ability to run of the application
Make sure that the application is compatible.
Check whether the system requirements are met.
Check whether the application can be installed on the Thin Client. This is done in the Admin role.
Check whether the application works smoothly.
If all conditions have been met, the application is compatible and able to run.

 

VERWEISZIELPUNKT
 
Adding an app
Open the Applications.
Click on +Add .
A new entry is created.
Open the entry.
Go to Icon, select a suitable symbol from the drop-down field.
Activate Autostart if you want the application to start automatically.
Under Name, enter the name of the application.
If you want to be able to call up the remote connection via the keyboard, use Hotkey to specify a hotkey.
Enter the file path to the program file on the Thin Client in the Path field.
If you want to define application-specific parameters, click on Parameters to enter a command line parameter. For information on possible parameters please refer to the manual of the application.
Under Application privilege level to specify how the application should be started.
Activate Close RemoteHMI menu on app start if you wish to close the firmware when starting the application.
If the application requires Administrator or extended authority, you can store the login data for the Administrator account under Use predefined admin login credentials. You then no longer need to enter the login data when starting the app.

 

Activate Use predefined admin login credentials if you want to start the application via the login data of the Thin Client. Enter the user name and the password.
Click on Min user role required to start app manually to define the lowest required user authority level for starting the application.
If the user is not authorised to start the application manually, it will be greyed out in the Applications register.

 

Click on  Apply  to accept the input.
The application will be displayed on the dashboard and in the Applications register.
Click on  Manage  to move the app in the list.
Click on [] to close the entry and return to the list.
Check whether the app opens correctly when clicking on the entry.

 

VERWEISZIELPUNKT

Managing apps

VERWEISZIELPUNKT
 
Moving an application in the list
In the Applications register, open the entry you want by clicking on .
Click on to move the entry up one place in the list.
Click on to move the entry down one place in the list.

 

 
Changing application settings
Open the entry you want in the Applications register.
Click on  Edit  to edit the settings.
Make the required changes.
Click on  Apply  to accept the changes.
Click on  Revert  to reject the changes.
Click on  Manage  to edit the list.

 

 
Copying an application
Check the compatibility and ability to run of the application before creating a link to a new application (see "Adding apps")
Open the Applications register.
Open the entry you want to copy.
Click on  Copy  to copy the application's settings.
A new entry is created.
Click on  Select File  and select the program in Windows Explorer.
Open the entry and change its settings as described under Adding apps.
Click on  Apply  to apply the changes.
Click on  Revert  to reject the changes.
Click on  Manage  to move the app in the list.
Click on [] to close the entry and return to the list.

 

VERWEISZIELPUNKT
 
Closing an application
In general, you should shut down applications properly to prevent any data loss. If you cannot shut down an application in the normal way you can force its termination.

 

Open the entry you want in the Applications register.
Click on  Terminate  to force the termination of the application.
Confirm the security message.
The application is shut down.

 

VERWEISZIELPUNKT
 
Deleting the link to the application
The  Delete  button only deletes the link to the application and does not de-install the application.
You can only de-install the program in the Windows user interface.

 

Open the entry you want in the Applications register.
Click on  Delete  to delete the link.
Confirm the security message.
The link to the app is deleted.

 

VERWEISZIELPUNKT

Creating and managing templates

VERWEISZIELPUNKT
 
Creating templates
Open Templates.
Click on  Add new Template .
Enter a name and confirm the entry.
The template will be added.

 

VERWEISZIELPUNKT
 
Editing templates
Open Templates.
Select the template you wish to edit.
The template will be opened for editing.

 

VERWEISZIELPUNKT
 
Transferring template to device
Open Templates.
Click on  Send configuration .
The Send configuration to device dialogue will pop up.
Select the device to which you want to transfer the template.
Use the Force Download function to force the download of all changes. It is not possible for the Thin Client user to abort the download.

 

Activate Force Download if you want to force the download.
Click on  Start transfer .
A progress bar shows how the data transfer is progressing.
If you want to abort the transfer, click on  Cancel .
The system will issue a message.

 

VERWEISZIELPUNKT

Creating and editing databases

VERWEISZIELPUNKT

You can save the templates and the firmware configurations of the connected devices in databases. The software saves the data in RDM files (name.rdm). You can protect these files with a password.

 

VERWEISZIELPUNKT
 
Opening the main menu
Click on to open the main menu.

 

VERWEISZIELPUNKT
 
Creating a database
Click on New Database to create a new database.
Enter a name.
Click on  Browse  to select a folder in which you want to save the database and confirm your selection.
Click on  Create database .
The new database will be opened.

 

VERWEISZIELPUNKT
 
Opening a database
Click on Open Database to open an existing database.
Click on "Browse" to select a database and confirm your selection.
Click on  Open .
The new database will be opened.

 

VERWEISZIELPUNKT
 
Creating or changing a password
The current database can be password-protected.

 

Click on Set / Reset Database password.
Enter a password (min. 5 characters long) and confirm.
The next time you open the database you will be asked to enter the password.

 

 
Deleting a password
Click on Set / Reset Database password.
Click on  Reset Password  to remove an existing password.
The database is now no longer password-protected.

 

VERWEISZIELPUNKT

Software settings

VERWEISZIELPUNKT
 
Opening the main menu
Click on to open the main menu.

 

VERWEISZIELPUNKT
 
Specifying and editing settings
Activate Open last database at start to open the database you last used after a re-start.
Click on Remote HMI Manager text size to specify the text size.
Click on Request Download Time to specify the time available to the firmware user to confirm or reject changes.
Only activate Enable Logfile when you are looking for a program error.

 

 

VERWEISZIELPUNKT
 
Accept or reject settings
Click on  Apply  to accept the settings.
Click on  Revert  to reject the changes.

 

VERWEISZIELPUNKT

Carrying out a firmware update

VERWEISZIELPUNKT
 
Opening the main menu
Click on to open the main menu.

 

VERWEISZIELPUNKT
 
Carrying out a firmware update
Our Support department will provide you with the update file.

 

Click on  Select Firmware File  to select the update file in the Windows Explorer.
Click on  Start Download  to download the update to the Thin Client.
A progress bar shows how far the update installation has progressed.
If an interval greater than 0 seconds has been specified under Request Download Timeout the Thin Client user can abort the download within this time. The system will issue a message that the download has been aborted.

 

If the update has been finished, the system will issue a message.

 

VERWEISZIELPUNKT

Error fixing

VERWEISZIELPUNKT

No connection possible between Remote HMI Device Manager and Thin Client

Cause

How to fix it

Who

Incorrect network configuration

Check network configuration.

Engineer

Access from Device Manager to Thin Client not permitted

Allow access in the System & Proxy menu.

Engineer

 

VERWEISZIELPUNKT

Configuration of the remote access

VERWEISZIELPUNKT
These settings can only be made at the Thin Client.

 

VERWEISZIELPUNKT
 
Configuration of remote access to the Thin Client via VNC and RDM
Activate Allow configuration export/import via RemoteHMI Device Manager to allow the export and import of the Thin Client configuration via the RemoteHMI Device Manager.
Activate Allow remote access via VNC to allow the VNC remote access to the Thin Client.
Enter the password for the remote control.
As an option, enter a password for remote access without operating permit.
Click on  Advanced VNC Server Config  if you need to change the VNC settings.
Click on Input blocking during remote access to define access behaviour during a remote connection.
Activate Off to allow local and remote operation during remote access.
Activate Local to block local operation of the Thin Client during remote access.
Activate Remote on local activity, inactivity timeout = 3 sec to block the remote operation via local operation during remote access.
This block is removed if no local operation occurs during a specified idle period. The factory setting for this idle period is 3 seconds. This can be adjusted.
To adjust the idle period, click on  Advanced VNC Server Config .

 

VERWEISZIELPUNKT

Activating VNC server system on the host

VERWEISZIELPUNKT

The following explains the procedure for the TightVNC server.

In order to be able to establish a VNC connection, the VNC server system must be activated on the host. The VNC service acquires the IP address needed for this connection from the settings of the PC's network connection. Depending on the configuration, the IP address is specified manually or allocated by a DHCP server. In the firmware's address book, this IP address is defined as the server IP of the VNC connection.

 

The way this connection is established depends on the settings of the VNC server and can either be
a direct connection that is not password-protected
a connection with VNC password
a connection with Windows password

 

VERWEISZIELPUNKT

VNC server parameters

VERWEISZIELPUNKT

The following parameters are necessary to configure the VNC connection. The actual name may vary depending on the VNC server system used.

 

VNC server address

The VNC server address is the same as the server IP address or the server name.

The VNC server systems usually have several ways to find out the address with which the server can be addressed in the network.

In addition to the IP address, port numbers can be allocated in the settings of the VNC server, with which the server can be addressed in the network.

The target address of the Host PC must be located in the network of the Thin Client or must be contactable from the Thin Client.

 

Ports

Accept connections on port

 

Defines the server connection port for data transmission (standard port 5900).

If you are using a different port due to network conflicts you need to configure this port. Check the settings of a firewall.

 

VNC password

VNC server applications authenticate users of a VNC connection via a password. The following password procedures are available:

 

None

No password is defined. The VNC server on the host allows access to each remote PC (Remote HMI) requesting a VNC connection via its address.

VNC password

Defines one or more passwords (depending on VNC server application) which the VNC server system requests from the Client for authentication purposes.

Windows password

Uses the Windows access authentication. The VNC server system grants the client access to the host if logged on with the valid Windows password.

Single sign on

Uses Windows access authentication and authentication via Windows-based login. The VNC server system grants access to the client if the user has entered a valid Windows login.

 

Encryption

Most VNC servers use encryption to protect the transmission of image, mouse and keyboard data from unauthorised access.

 

Always on

Data is always encrypted

Prefer on

Data is always encrypted unless the Thin Client requests no encryption (standard). This setting is necessary if the configuration requests no encryption.

Prefer off

Data is not encrypted unless the Thin Client requests encryption. This setting is necessary if the configuration requests encryption.

 

Prompt local user to accept connections

Allows the host user to accept or reject a connection request. Since the host is usually used for direct remote access, this setting is not relevant for the Thin Client connection.

 

Start VNC Server automatically with Windows

Specifies that the VNC server system is automatically activated when Windows is started. If this function is not activated, the remote access must be explicitly started after a system start of the host PC.

 

VERWEISZIELPUNKT

DRDC-Client connection

VERWEISZIELPUNKT

EMERSON's DeltaV®-Remote-Desktop-Connection-Client (DRDC) allows access to a virtualised operator or engineering workstation within a DeltaV®-virtualisation architecture. This way, applications that run on a distributed control system can be accessed via the Ethernet.

You can add a DRDC connection via an app in the Applications register (see Adding apps).

 

VERWEISZIELPUNKT
Requires a Pro licence.

 

VERWEISZIELPUNKT

Updating the software

VERWEISZIELPUNKT
For the software to be updated, the current software version must first be de-installed.

 

VERWEISZIELPUNKT
De-install the old software version.
Double-click on the ...Setup.exe update file.
Follow the instructions of the installation assistant.
A progress bar tracks the progress of the installation. Once the installation has been completed, the system will issue a message.
Open the software.
During the start you can either open an existing database or create a new one.