<?xml version="1.0" encoding="UTF-8"?>
<Configuration>
	<DTMInformation>
		<FDT xmlns="x-schema:DTMInformationSchema.xml" xmlns:fdt="x-schema:FDTDataTypesSchema.xml">
			<DtmInfo>
				<FDTVersion major="1" minor="2"/>
				<fdt:VersionInformation name="HART Mux DTM" version="" vendor="R. STAHL Schaltgeräte GmbH" date="2012-01-23"/>
				<DtmDeviceTypes>
					<fdt:DtmDeviceType deviceTypeId="6" manufacturerId="158">
						<fdt:VersionInformation name="HART MUX 9192 16 Channels" version="" vendor="R. STAHL Schaltgeräte GmbH" date="2012-01-23"/>
						<fdt:SupportedLanguages>
							<!-- en -->
							<fdt:LanguageId languageId="9"/>
							<fdt:LanguageId languageId="7"/>
							<fdt:LanguageId languageId="1033"/>
							<fdt:LanguageId languageId="1031"/>
						</fdt:SupportedLanguages>
						<fdt:BusCategories>
							<fdt:BusCategory busCategory="036D1498-387B-11D4-86E1-00E0987270B9" busCategoryName="HART">
								<fdt:CommunicationTypeEntry communicationType="supported"/>
							</fdt:BusCategory>
							<fdt:BusCategory busCategory="9A6F1E24-D69A-4FF7-B5B9-0192B958D30D" busCategoryName="HART multiplexer">
								<fdt:CommunicationTypeEntry communicationType="required"/>
							</fdt:BusCategory>
						</fdt:BusCategories>
						<fdt:DeviceIcon path="ispac.ico"/>
					</fdt:DtmDeviceType>
					<fdt:DtmDeviceType deviceTypeId="7" manufacturerId="158">
						<fdt:VersionInformation name="HART MUX 9192 32 Channels" version="" vendor="R. STAHL Schaltgeräte GmbH" date="2012-01-23"/>
						<fdt:SupportedLanguages>
							<!-- en -->
							<fdt:LanguageId languageId="9"/>
							<fdt:LanguageId languageId="7"/>
							<fdt:LanguageId languageId="1033"/>
							<fdt:LanguageId languageId="1031"/>
						</fdt:SupportedLanguages>
						<fdt:BusCategories>
							<fdt:BusCategory busCategory="036D1498-387B-11D4-86E1-00E0987270B9" busCategoryName="HART">
								<fdt:CommunicationTypeEntry communicationType="supported"/>
							</fdt:BusCategory>
							<fdt:BusCategory busCategory="9A6F1E24-D69A-4FF7-B5B9-0192B958D30D" busCategoryName="HART multiplexer">
								<fdt:CommunicationTypeEntry communicationType="required"/>
							</fdt:BusCategory>
						</fdt:BusCategories>
						<fdt:DeviceIcon path="ispac.ico"/>
					</fdt:DtmDeviceType>
					<fdt:DtmDeviceType deviceTypeId="5" manufacturerId="158">
						<fdt:VersionInformation name="IS1 HART MUX" version="" vendor="R. STAHL Schaltgeräte GmbH" date="2012-01-23"/>
						<fdt:SupportedLanguages>
							<!-- en -->
							<fdt:LanguageId languageId="9"/>
							<fdt:LanguageId languageId="7"/>
							<fdt:LanguageId languageId="1033"/>
							<fdt:LanguageId languageId="1031"/>
						</fdt:SupportedLanguages>
						<fdt:BusCategories>
							<fdt:BusCategory busCategory="9A6F1E24-D69A-4FF7-B5B9-0192B958D30D" busCategoryName="HART multiplexer">
								<fdt:CommunicationTypeEntry communicationType="required"/>
							</fdt:BusCategory>
							<fdt:BusCategory busCategory="036D1498-387B-11D4-86E1-00E0987270B9" busCategoryName="HART">
								<fdt:CommunicationTypeEntry communicationType="supported"/>
							</fdt:BusCategory>
						</fdt:BusCategories>
						<fdt:DeviceIcon path="is1.ico"/>
					</fdt:DtmDeviceType>
					<fdt:DtmDeviceType deviceTypeId="4" manufacturerId="158">
						<fdt:VersionInformation name="HART MUX 9148" version="" vendor="R. STAHL Schaltgeräte GmbH" date="2012-01-23"/>
						<fdt:SupportedLanguages>
							<!-- en -->
							<fdt:LanguageId languageId="9"/>
							<fdt:LanguageId languageId="7"/>
							<fdt:LanguageId languageId="1033"/>
							<fdt:LanguageId languageId="1031"/>
						</fdt:SupportedLanguages>
						<fdt:BusCategories>
							<fdt:BusCategory busCategory="036D1498-387B-11D4-86E1-00E0987270B9" busCategoryName="HART">
								<fdt:CommunicationTypeEntry communicationType="supported"/>
							</fdt:BusCategory>
							<fdt:BusCategory busCategory="9A6F1E24-D69A-4FF7-B5B9-0192B958D30D" busCategoryName="HART multiplexer">
								<fdt:CommunicationTypeEntry communicationType="required"/>
							</fdt:BusCategory>
						</fdt:BusCategories>
						<fdt:DeviceIcon path="icsmodul.ico"/>
					</fdt:DtmDeviceType>
					<fdt:DtmDeviceType deviceTypeId="3" manufacturerId="158">
						<fdt:VersionInformation name="HART MUX VOS200" version="" vendor="R. STAHL Schaltgeräte GmbH" date="2012-01-23"/>
						<fdt:SupportedLanguages>
							<!-- en -->
							<fdt:LanguageId languageId="9"/>
							<fdt:LanguageId languageId="7"/>
							<fdt:LanguageId languageId="1033"/>
							<fdt:LanguageId languageId="1031"/>
						</fdt:SupportedLanguages>
						<fdt:BusCategories>
							<fdt:BusCategory busCategory="036D1498-387B-11D4-86E1-00E0987270B9" busCategoryName="HART">
								<fdt:CommunicationTypeEntry communicationType="supported"/>
							</fdt:BusCategory>
							<fdt:BusCategory busCategory="9A6F1E24-D69A-4FF7-B5B9-0192B958D30D" busCategoryName="HART multiplexer">
								<fdt:CommunicationTypeEntry communicationType="required"/>
							</fdt:BusCategory>
						</fdt:BusCategories>
						<fdt:DeviceIcon path="icsmux.ico"/>
					</fdt:DtmDeviceType>
				</DtmDeviceTypes>
			</DtmInfo>
		</FDT>
	</DTMInformation>
	<!-- Use lower letters for the name -->
	<Images>
		<!-- Images shown in the user interface identification area -->
		<!-- Note: in the DTM we use the attribute deviceTypeId for the device image lookup -->
		<Image name="device" deviceTypeId="6" file="ispac.bmp"/>
		<Image name="company" deviceTypeId="6" file="company.bmp"/>
		<Image name="device" deviceTypeId="7" file="ispac.bmp"/>
		<Image name="company" deviceTypeId="7" file="company.bmp"/>
		<Image name="device" deviceTypeId="5" file="is1.bmp"/>
		<Image name="company" deviceTypeId="5" file="company.bmp"/>
		<!-- 9148 -->
		<Image name="device" deviceTypeId="4" file="icsmodul.bmp"/>
		<Image name="company" deviceTypeId="4" file="company.bmp"/>
		<!-- VOS200 -->
		<Image name="device" deviceTypeId="3" file="icsmux.bmp"/>
		<Image name="company" deviceTypeId="3" file="company.bmp"/>
		<Image name="icon" deviceType="*" file="icon.ico"/>
	</Images>
	<Properties>
		<!-- The automatic synchronizaion from HART to FDT tag is configurable. -->
		<!-- value=0 => off, value=1 => on -->
		<Property name="AutomaticSyncFromHARTtoFDTtag" value="0"/>
		<!-- 
    logLevel=0 => off
    logLevel=1 => LOG_LEVEL_ERROR
    logLevel=2 => LOG_LEVEL_WARNING
    logLevel=3 => LOG_LEVEL_INFO
    logLevel=4 => LOG_LEVEL_TRACE
    logLevel=5 => LOG_LEVEL_LIBRARY_TRACE
-->
		<Logger>
			<Property name="logLevel" value="0"/>
			<!-- Just the filename, no path. Path will be constructed during runtime -->
			<Property name="logFile" value="StahlMuxDTM.log"/>
			<Property name="logTruncate" value="1"/>
			<Property name="maxSizeInBytes" value="10000000"/>
			<Property name="numberOfMaxLogFiles" value="3"/>
		</Logger>
		<AboutUI>
			<Property name="copyrightText" value="Copyright(c) - R. STAHL Schaltgeräte GmbH"/>
		</AboutUI>
		<!-- This is for backup only and only applies if the communication DTM does not send a response message -->
		<Property name="FdtCommunicationTimeout" value="30000"/>
		<Property name="DelayedResponseTimeout" value="8000"/>
		<Property name="MultiplexerResetTimeout" value="120000"/>
		<!-- Sends sent and received messages to the debugger port -->
		<Property name="EnableDebugTracing" value="0"/>
		<Property name="ManufacturerLookupFile" value="HartInformation.xml"/>
	</Properties>
</Configuration>