Non-Ex i isolator

Safety and a wide range of signal conditioner isolators
Isolators featuring galvanic separation can be used for decoupling, filtering and signal adaptation. The non-Ex i / non-I.S. isolators are a perfect addition to R. STAHL's isolating barriers with intrinsically safe interface. The dual-channel versions offer a high channel density.

To make your life easier, R. STAHL's ISpac isolators use pac-Bus: All you need to do is snap the device onto the DIN rail and pac-Bus and it is already connected to the power supply; line fault siganliazation is easy to read.

Our non-I.S. isolators are also designed to be user-friendly in operation: Two-channel modules for all functions save space, and the three-way reporting of wire breakage and short circuiting speeds up diagnostics. They also boast an impressively long service life of 15 years. And their certification for use in ships' engine rooms bears testimony to their robust construction.

R. STAHL's ISpac isolators are designed with functional safety in mind. These products conform to SIL 2 and SIL 3, including devices with trip amplifier function.

  • Compact: Time-saving system for wiring: pac-Bus
  • Trip amplifier functions for SIL applications up to SIL 2
  • HART-capable

Filter product lines

Select the product lines that are applicable to your intended use.

Certificates SAP
Zone Filter
Min. ambient temperature
Max. ambient temperature
Type of protection (IP)(calc)
Signal types
Product Description
Connection type

4 Series (10 Products)

Transmitter Supply Unit with Limit Value Series 9162 - Non Ex i / non I.S.

  • Compact limit value switch with two configurable limit values and output of 4 to 20 mA
  • Bidirectional HART transmission
  • Can be used up to SIL 2 (IEC/EN 61508)

mA-Isolating Repeater Series 9164 - Non Ex i / non I.S.

  • Interconnection of two mA-sources and active 2-wire inputs is possible
  • Ideal solution for integrating 4-wire transmitters into analogue input supplies.
  • Bidirectional HART transmission 4 ... 20 mA
  • Galvanic isolation between input and output

Temperature Transmitter Series 9182 - Non Ex i / non I.S.

  • Temperature transmitter, can be configured for virtually any common sensor type
  • Broad range, including variants with signal conversion and trip amplifier function
  • Can be used up to SIL 2 (IEC/EN 61508)

Ask our Experts

Previous

Contact form

*Mandatory fields
Previous

We'll be glad to call you back to support you.

Wir rufen Sie gerne für ein Beratungsgespräch zurück. EN
*Mandatory