Analogue I/O modules

Universal modules for analogue inputs and outputs (AIOM) in hazardous areas
Analogue input? Analogue output? With R. STAHL's universal modules (analogue I/O modules, or AIOM for short), anything is possible: Each of the eight channels can be used individually as either an input or an output, transmitting the data in both directions to connected HART field devices. The inputs/outputs for 0/4 to 20 mA and HART are "ia" intrinsically safe and short-circuit proof.

HART analogue universal modules can be used to connect up to eight intrinsically safe analogue unit signals (0/4 to 20 mA) to the IS1+ remote I/O system. Digital communication with connected field devices can take place in both directions using the HART protocol.

Each channel can be used as an input for connecting two-, three- or four-conductor transmitters, or as an output for connecting positioners or indicators. The Ex i inputs/outputs are short-circuit proof and galvanically separated from the system.

A blue LED and diagnostic messages provide early warnings that maintenance is required in order to avoid system downtime.
The Zone 1 versions have additional LEDs for each channel to indicate any line faults.

  • Multi-functional: Each channel can be used individually as an input or an output
  • Versions with Ex ia inputs/outputs for installation in Zone 1 or Zone 2
  • Hot-swappable: Can be replaced while the system is in operation

Filter product lines

Select the product lines that are applicable to your intended use.

Scope
Zones
Application range (Zone)
Ex interface zone
Max. Voltage Uo
Max. Current Io
Max. Demand Po

4 Series (5 Products)

Analog Universal Module HART for Zone 1 Series 9468/32

  • Eight channels can be used individually as inputs or outputs
  • intrinsically safe Ex ia IIC inputs/outputs with line fault monitoring and LED error indication for each channel
  • module in Zone 1 can be hot swapped

Analog Universal Module HART for Zone 2 Series 9468/33

  • Eight channels can be used individually as inputs or outputs
  • intrinsically safe Ex ia IIC inputs/outputs with line fault monitoring
  • module in Zone 2 can be hot swapped

Safety Analog Input Module HART Ex i Inputs, 8/6 Channels Series 9462

  • For applications up to SIL 2 using PROFIsafe in Zone 1
  • six or eight channels for two-conductor HART transmitters
  • intrinsically safe Ex i IIC inputs with line fault monitoring

Universal Module HART Zone 2 Ex n Series 9469/35

  • 8 channels can be used as analogue inputs or outputs, and 4 of these channels can used as binary inputs or outputs
  • Ex nA inputs/outputs with line fault monitoring, an LED fault and status display for each channel and SIL2 shutdown input
  • Module in Zone 2 can be replaced during operation (hot swap)