Analogue I/O modules

Universal modules for analogue inputs and outputs (AIOM) in hazardous areas
Analogue input? Analogue output? With R. STAHL's universal modules (analogue I/O modules, or AIOM for short), anything is possible: Each of the eight channels can be used individually as either an input or an output, transmitting the data in both directions to connected HART field devices. The inputs/outputs for 0/4 to 20 mA and HART are "ia" intrinsically safe and short-circuit proof.

HART analogue universal modules can be used to connect up to eight intrinsically safe analogue unit signals (0/4 to 20 mA) to the IS1+ remote I/O system. Digital communication with connected field devices can take place in both directions using the HART protocol.

Each channel can be used as an input for connecting two-, three- or four-conductor transmitters, or as an output for connecting positioners or indicators. The Ex i inputs/outputs are short-circuit proof and galvanically separated from the system.

A blue LED and diagnostic messages provide early warnings that maintenance is required in order to avoid system downtime.
The Zone 1 versions have additional LEDs for each channel to indicate any line faults.

  • Multi-functional: Each channel can be used individually as an input or an output
  • Versions with Ex ia inputs/outputs for installation in Zone 1 or Zone 2
  • Hot-swappable: Can be replaced while the system is in operation

Filter product lines

Select the product lines that are applicable to your intended use.

Scope
Zones
Zone & Division
Application range (Zone)
Ex interface zone
Max. Voltage Uo

3 Series (3 Products)

Analog Universal Module HART for Zone 1 / CIass I, Div. 1 Series 9468/32

  • Eight channels can be used individually as inputs or outputs
  • Intrinsically safe Ex ia inputs/outputs with line fault monitoring and LED error indication for each channel
  • module hot swap in Zone 1 and Class I, Div. 1

Analog Universal Module HART for Zone 2 / Class I, Div 2 Series 9468/33

  • Eight channels can be used individually as inputs or outputs
  • Intrinsically safe Ex ia inputs/outputs with line fault monitoring
  • module hot swap in Zone 2 and Class I, Div. 2

Universal Module HART for Zone 2, CIass I, Div. 2 nonincendive Series 9469/35

  • Eight channels can be used as analog inputs or outputs, and 4 of these channels can be used as binary inputs or outputs
  • Inputs/outputs Ex ec with line fault monitoring, LED fault and status display for each channel and SIL2 shutdown input
  • module hot swap in Zone 2 and Class I, Div. 2